bluesea.com APPENDIX 167 TEST MONTHLY ELCI 30A AC Shore Power Source Main Circuit Breaker Branch Circuit Breaker 120V - 30A 3,000 3,000 120V - 50A 3,000 3,000 120/240V - 50A 5,000 3,000 240V - 50A 5,000 3,000 120 Volt–60 Hz ELCI Circuit Breaker 120/240 Volt–60 Hz 230 Volt–50 Hz Hot Neutral Ground 120/240 Volt–60 Hz Ground Hot 1 Hot 2 Neutral 120 Volt–60 Hz Hot Neutral Ground AC Main Power Distribution and Circuit Protection Purpose ȏ 3roYide a path Ior deliYerinJ power IroP the shipȇs sources oI $& power to the AC branch distribution system ȏ 3roYide a path Ior returninJ Iault currents to Jround Yia the Jreen safety Ground wire ȏ 3roYide a Peans Ior disconnectinJ $& power when the boat is not in use or in emergencies ȏ 3roYide electrical separation to insure that two sources oI $& power are never connected ȏ 3roYide circuit protection Ior neutral and line wires in the $& main system ȏ 3roYide Jround Iault protection ȏ 3roYide (/&I oYerload or leaNaJe Iault protection AC Wire Systems The three most common AC systems used on boats are shown here. In all cases the ground, sometimes called safety ground to clarify its purpose and di΍erentiate it IroP the '& Jround or neJatiYe is said to be a “normally non-current carrying wire.” Its purpose is to provide the lowest resistance path for AC currents that have strayed from their proper containment in the normally current carrying hot and neutral wires. The ground wire is connected to the exterior conductive parts of AC devices that could be touched by a person during normal operation, and it conducts errant AC currents safely to ground rather than passing them through a human body. The ground wire is never passed through a circuit breaker. Devices Qualifying as AC Main Circuit Breakers In order to qualify as an AC main circuit breaker, these characteristics must be present: 1. 7he circuit breaNer Pust haYe an $PperaJe Interrupt &apacit\ $I& meeting the requirements of the following tables. 2. 7he circuit breaNer Pust be Pultiple pole usuall\ or 3. The circuit breaker must be rated for the appropriate AC system voltage in which it will be used. 4. The circuit breaker must be available in amperages appropriate to the design amperage of the system. In the USA, this is generally 30A and $ while (uropean s\stePs are Jenerall\ $ and $ 5. The ELCI shall have a leakage trip mechanism that trips if current exceeding 30mA leaks to ground. Sources of AC power, whether shore power or onboard generators and inverters, should always have a circuit breaker near the power source. This circuit breaker is designated the AC main circuit breaker. The AC main circuit breaker should always have a pole for each of the hot and neutral wires in the circuit assuring that circuit protection functions are not compromised in reverse polarity situations %eJinninJ in -ul\ $%<& 6tandards reTuire that an (TuipPent /eaNaJe &ircuit Interrupter (/&I with a P$ leaNaJe trip be installed in shore power applications as the first protectiYe device after the power inlet. ELCIs respond to leakage of electrical current outside of the intended current path, and provide overload and short circuit protection. They serve as the main AC circuit breaker for the system. These devices will open all energized conductors and the neutral when opened manually or tripping on an overload or leakage fault. For a more complete discussion of ELCIs, s ee paJe ELCI Circuit Breaker 3104 230 Volt–50 Hz RCBO

RkJQdWJsaXNoZXIy MjgzMDI=