2020 Blue Sea Systems Catalog

bluesea.com 136 METERS DC Analog Meters Meters with backlighting for low light conditions • Includes appropriate external DC shunt (p. 147) when required • Backlit meter face (separate 12 or 24V DC backlight connections) • DIN Meters include a terminal cover included to prevent accidental short circuit • DIN Meters are a standard European 72mm design • DIN Meter face is white matte with black printed scale and knife-edge pointer DC Analog Voltmeter Panels Enables voltage monitoring on up to 3 battery banks with one analog meter • Includes standard 8003 DC Analog Voltmeter • Displays voltage from 8–16V DC • 3 position switch for multiple battery banks 8015 Traditional Metal 5.25" x 3.75" (133.35mm x 95.25mm) 1473 360 Panel System 4.88" x 4.75" (123.83mm x 120.65mm) PN Function Operating Amps (Meter) Operating Amps (Backlight) Shunt Type Connection 8038 Micro Ammeter 0–15A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC Internal 2 wire inline, 3 connections for backlight 8041 Micro Ammeter 0–50A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 8005 Standard Ammeter 0–25A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC Internal 2 wire inline, 3 connections for backlight 8022 Standard Ammeter 0–50A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 8017 Standard Ammeter 0–100A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 8018 Standard Ammeter 0–150A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 8019 Standard Ammeter 0–200A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 1052 DIN Ammeter 0–25A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC Internal 2 wire inline, 3 connections for backlight 1053 DIN Ammeter 0–50A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 1054 DIN Ammeter 0–100A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 1055 DIN Ammeter 0–150A DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight PN Function Shunt Type Connection Meter Face Size in (mm) 8252* Zero Center Ammeter 50–0–50A DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 2.75 (69.85) 8253* Zero Center Ammeter 100–0–100A DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 2.75 (69.85) 8254* Zero Center Micro Ammeter 50–0–50A DC External—50 mV at meter full scale 2 wire from shunt, 3 connections for backlight 2.00 (50.80) 8003 8028 8005 8038 8253 8254 *Meters read both discharge and charge current 1050 1052 PN Function Operating Amps (Meter) Operating Amps (Backlight) Connection 8028 Micro Voltmeter 8–16V DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight 8243 Micro Voltmeter 18–32V DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight 8003 Standard Voltmeter 8–16V DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight 8240 Standard Voltmeter 18–32V DC 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight 1050 DIN Voltmeter 0–16V 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight 1051 DIN Voltmeter 18–32V 1 mA at full scale 16 mA@12V DC, 20 mA@24V DC 2 wire, 3 connections for backlight

RkJQdWJsaXNoZXIy MjgzMDI=