bluesea.com CIRCUIT PROTECTION 83 • White actuator indicates OFF position • Single pole is available in Flat Rocker and Restricted Off styles • Single pole is frequently used for AC or DC Branch circuit protection • Double pole is available in Flat Rocker and Raised Rocker styles • Double pole is typically used for AC Main circuit protection • Raised Rocker actuator style is used for AC source selection on the 360 Panel System • International ON and OFF symbols support vertical or horizontal mounting 0.200" 5.08mm 0.156" DIA Ø3.96mm 0.750" 19.05mm TYP PER POLE 1.660" 42.16mm 0.750" 19.05mm 1.260" 32.00mm 1.239" 31.47mm OVERALL DEPTH 2.40" 60.96mm 0.750" 19.05mm 1.660" 42.16mm 2.217" 56.31mm Interrupting Capacity Table (see ABYC Requirements p. 164) 1.245" 31.62mm OVERALL DEPTH 2.40" 60.96mm 1.500" 38.10mm 2.310" 58.67mm A-Series Rocker Circuit Breakers Combines switching and circuit protection into a single device Cutout Dimensions 7574 Raised Rocker • Standard circuit breaker for AC Source Select panels in the 360 Panel System I 30A 7403 Flat Rocker • Standard circuit breaker used on the 360 Panel System (1200 Series) • Flat actuator resists accidental switching by being flush in the ON position I 50 7425 Restricted-OFF Rocker • Actuator shows white in the OFF position • Restricted OFF actuator can only be switched to OFF by insertion of small screwdriver into slot I 50 Part # Amps Max. Poles Rocker Actuator 7399 2.5A 32V DC 1 Flat 7400 5A 32V DC 1 Flat 7425 5A 32V DC 1 Restricted-OFF 7401 8A 32V DC 1 Flat 7402 10A 32V DC 1 Flat 7427 10A 32V DC 1 Restricted-OFF 7403 15A 32V DC 1 Flat 7428 15A 32V DC 1 Restricted-OFF 7404 20A 32V DC 1 Flat 7429 20A 32V DC 1 Restricted-OFF 7405 25A 32V DC 1 Flat 7430 25A 32V DC 1 Restricted-OFF 7406 30A 32V DC 1 Flat 7407 40A 32V DC 1 Flat 7408 50A 32V DC 1 Flat 7433 50A 32V DC 1 Restricted-OFF Related Products 360 Panel System page 116 Part # Amps Max. Poles Rocker Actuator 7410 10A 32V DC 2 Flat 7411 15A 32V DC 2 Flat 7412 16A 32V DC 2 Flat 7413 20A 32V DC 2 Flat 7574 30A 32V DC 2 Raised 7414 30A 32V DC 2 Flat 7575 32A 32V DC 2 Raised 7415 32A 32V DC 2 Flat 7416 40A 32V DC 2 Flat 7577 50A 32V DC 2 Raised 7417 50A 32V DC 2 Flat Voltage Nominal Operating 120/240V AC Temperature Operating -40°C to 85°C (-40°F to 185°F) Switching Cycles 10,000 @ rated amps and volts Type Magnetic Hydraulic – Trip free Terminal Screw #10-32 Stainless Steel Terminal Screw Torque 14–15 in-lb Recommended Trip Time Delay See bluesea.com Mounting Screw #6-32 Stainless Steel (included) Mounting Nut Torque 6–8 in-lb Recommended Regulatory CE marked, TUV certified, CSA certified, UL 1077 recognized UL 1077 - UL/CSA (US/Canada) EN60934 - TUV (Europe) Volts Amps DC Interrupt AC Interrupt AC Interrupt 1 Pole 32V DC –– 5,000A, U2, OL1 –– –– 65V DC –– 7,500A, U1, OL1 –– –– 125V AC 2-30A –– 3,000A, U2, OL1 –– 40-50A –– 1,500A, U2, OL1 250V AC 2-30A –– 1,500A, U2, OL0 1,500A 40-50A –– 3,000A, U1, OL0 2 Pole 32V DC –– 5,000A, U2, OL1 –– –– 65V DC –– 7,500A, U1, OL1 –– –– 125V AC –– –– 3,000A, U2 –– 250V AC 2-30A –– 3,000A, U2, OL1 1,500A 40-50A –– 3,000A, U2, OL0
RkJQdWJsaXNoZXIy MjgzMDI=